Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
2.
Pathology ; 52(7): 754-759, 2020 Dec.
Article in English | MEDLINE | ID: covidwho-1044714

ABSTRACT

The unprecedented scale of testing required to effectively control the coronavirus disease (COVID-19) pandemic has necessitated urgent implementation of rapid testing in clinical microbiology laboratories. To date, there are limited data available on the analytical performance of emerging commercially available assays for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) and integration of these assays into laboratory workflows. Here, we performed a prospective validation study of a commercially available assay, the AusDiagnostics Coronavirus Typing (8-well) assay. Respiratory tract samples for SARS-CoV-2 testing were collected between 1 March and 25 March 2020. All positive samples and a random subset of negative samples were sent to a reference laboratory for confirmation. In total, 2673 samples were analysed using the Coronavirus Typing assay. The predominant sample type was a combined nasopharyngeal/throat swab (2640/2673; 98.8%). Fifty-four patients were positive for SARS-CoV-2 (2.0%) using the Coronavirus Typing assay; 53/54 (98.1%) positive results and 621/621 (100%) negative results were concordant with the reference laboratory. Compared to the reference laboratory gold standard, sensitivity of the Coronavirus Typing assay for SARS-CoV-2 was 100% (95% CI 93.2-100%), specificity 99.8% (95% CI 99.1-100%), positive predictive value 98.1% (95% CI 90.2-99.7%) and negative predictive value 100% (95% CI 99.4-100%). In many countries, standard regulatory requirements for the introduction of new assays have been replaced by emergency authorisations and it is critical that laboratories share their post-market validation experiences, as the consequences of widespread introduction of a suboptimal assay for SARS-CoV-2 are profound. Here, we share our in-field experience, and encourage other laboratories to follow suit.


Subject(s)
COVID-19 Nucleic Acid Testing/methods , COVID-19/diagnosis , Multiplex Polymerase Chain Reaction/methods , Adult , Female , Humans , Male , Middle Aged , SARS-CoV-2 , Sensitivity and Specificity , Workflow
3.
Pathology ; 52(7): 796-800, 2020 Dec.
Article in English | MEDLINE | ID: covidwho-1041519

ABSTRACT

The severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) pandemic has significantly increased demand on laboratory throughput and reagents for nucleic acid extraction and polymerase chain reaction (PCR). Reagent shortages may limit the expansion of testing required to scale back containment measures. The aims of this study were to investigate the viability of sample pooling as a strategy for increasing test throughput and conserving PCR reagents; and to report our early experience with pooling of clinical samples. A pre-implementation study was performed to assess the sensitivity and theoretical efficiency of two, four, and eight-sample pools in a real-time reverse transcription PCR-based workflow. A standard operating procedure was developed and implemented in two laboratories during periods of peak demand, inclusive of over 29,000 clinical samples processed in our laboratory. Sensitivity decreased (mean absolute increase in cycle threshold value of 0.6, 2.3, and 3.0 for pools of two, four, and eight samples, respectively) and efficiency increased as pool size increased. Gains from pooling diminished at high disease prevalence. Our standard operating procedure was successfully implemented across two laboratories. Increased workflow complexity imparts a higher risk of errors, and requires risk mitigation strategies. Turnaround time for individual samples increased, hence urgent samples should not be pooled. Pooling is a viable strategy for high-throughput testing of SARS-CoV-2 in low-prevalence settings.


Subject(s)
COVID-19 Nucleic Acid Testing/methods , COVID-19/diagnosis , Specimen Handling/methods , COVID-19/epidemiology , Humans , Prevalence , SARS-CoV-2 , Sensitivity and Specificity , Workflow
4.
J Med Microbiol ; 70(2)2021 Feb.
Article in English | MEDLINE | ID: covidwho-955729

ABSTRACT

Saliva has recently been proposed as a suitable specimen for the diagnosis of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). Use of saliva as a diagnostic specimen may present opportunities for SARS-CoV-2 reverse transcription polymerase chain reaction (RT-PCR) testing in remote and low-resource settings. Determining the stability of SARS-CoV-2 RNA in saliva over time is an important step in determining optimal storage and transport times. We undertook an in vitro study to assess whether SARS-CoV-2 could be detected in contrived saliva samples. The contrived saliva samples comprised 10 ml pooled saliva spiked with gamma-irradiated SARS-CoV-2 to achieve a concentration of 2.58×104 copies ml SARS-CoV-2, which was subsequently divided into 2 ml aliquots comprising: (i) neat saliva; and a 1 : 1 dilution with (ii) normal saline; (iii) viral transport media, and (iv) liquid Amies medium. Contrived samples were made in quadruplicate, with two samples of each stored at either: (i) room temperature or (ii) 4 °C. SARS-CoV-2 was detected in all SARS-CoV-2 spiked samples at time point 0, day 1, 3 and 7 at both storage temperatures using the N gene RT-PCR assay and time point 0, day 1 and day 7 using the Xpert Xpress SARS-CoV-2 (Cepheid, Sunnyvale, USA) RT-PCR assay. The ability to detect SARS-CoV-2 in saliva over a 1 week period is an important finding that presents further opportunities for saliva testing as a diagnostic specimen for the diagnosis of SARS-CoV-2.


Subject(s)
COVID-19 Testing/methods , COVID-19/diagnosis , RNA, Viral/analysis , SARS-CoV-2/genetics , Saliva/virology , Humans , Molecular Diagnostic Techniques , Reverse Transcriptase Polymerase Chain Reaction , SARS-CoV-2/isolation & purification , Specimen Handling
5.
Med J Aust ; 213(6): 276-279, 2020 09.
Article in English | MEDLINE | ID: covidwho-696938

ABSTRACT

OBJECTIVES: To design and evaluate 3D-printed nasal swabs for collection of samples for SARS-CoV-2 testing. DESIGN: An iterative design process was employed. Laboratory evaluation included in vitro assessment of mock nasopharyngeal samples spiked with two different concentrations of gamma-irradiated SARS-CoV-2. A prospective clinical study compared SARS-CoV-2 and human cellular material recovery by 3D-printed swabs and standard nasopharyngeal swabs. SETTING, PARTICIPANTS: Royal Melbourne Hospital, May 2020. Participants in the clinical evaluation were 50 hospital staff members attending a COVID-19 screening clinic and two inpatients with laboratory-confirmed COVID-19. INTERVENTION: In the clinical evaluation, a flocked nasopharyngeal swab sample was collected with the Copan ESwab and a mid-nasal sample from the other nostril was collected with the 3D-printed swab. RESULTS: In the laboratory evaluation, qualitative agreement with regard to SARS-CoV-2 detection in mock samples collected with 3D-printed swabs and two standard swabs was complete. In the clinical evaluation, qualitative agreement with regard to RNase P detection (a surrogate measure of adequate collection of human cellular material) in samples collected from 50 hospital staff members with standard and 3D-printed swabs was complete. Qualitative agreement with regard to SARS-CoV-2 detection in three pairs of 3D-printed mid-nasal and standard swab samples from two inpatients with laboratory-confirmed SARS-CoV-2 was also complete. CONCLUSIONS: Using 3D-printed swabs to collect nasal samples for SARS-CoV-2 testing is feasible, acceptable to patients and health carers, and convenient.


Subject(s)
Clinical Laboratory Techniques/instrumentation , Coronavirus Infections/diagnosis , Diagnostic Techniques, Respiratory System/instrumentation , Patient Acceptance of Health Care/statistics & numerical data , Pneumonia, Viral/diagnosis , Printing, Three-Dimensional , Adult , Betacoronavirus/isolation & purification , COVID-19 , COVID-19 Testing , Female , Humans , Male , Middle Aged , Nasopharynx/virology , Pandemics , SARS-CoV-2
SELECTION OF CITATIONS
SEARCH DETAIL